line
line
Leading Edge Technology For Unsurpassed fire Protection

Type of Barrier

Wet mils

Dry mils

Coverage Rate

ICC ESR

Thermal Barrier Icynene MDC 200 CC 2 lb.

22

14.3

73 sq. ft. per gal

ESR 3199

Thermal Barrier Icynene LD-C-50 OC 0.5 lb.

20

13

80 sq. ft. per gal

ESR 1826

Ignition Barrier Icynene LD-R-50 OC 0.5 lb.

8

6

200 sq. ft. per gal

ESR 2715

Ignition Barrier Icynene LD-C-50 OC 0.5 lb.

4

3

400 sq. ft. per gal

 

MSDS

Application Data Guide

Spray Foam Insulation

The International Building Code mandates that polyurethane spray foam be separated from the interior of the building by a 15 minute thermal barrier or other approved covering.  DC315 passed certified NFPA 286 over closed and open cell for 15 minutes. It complies with the requirements of 2006 IBC Section 803.2.1 & 2009 IBC Section 803.1.2 and Section 2603.9 under Special Approvals for Thermal Barriers over Foam Plastics.